Connection Pool: fix LRFU implementation to not actually be LRU
The numbers of the native time unit were so small the CRF was always 1, making it an LRU. This commit switches the time to miliseconds and changes the time delta multiplier to the one yielding mostly highest hit rates according to the paper
This commit is contained in:
parent
9b73c35ca8
commit
a705637dcf
1 changed files with 3 additions and 3 deletions
|
@ -12,7 +12,7 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do
|
|||
def init([key, uri, opts, client_pid]) do
|
||||
with {:ok, conn_pid} <- Gun.Conn.open(uri, opts),
|
||||
Process.link(conn_pid) do
|
||||
time = :erlang.monotonic_time()
|
||||
time = :erlang.monotonic_time(:millisecond)
|
||||
|
||||
{_, _} =
|
||||
Registry.update_value(@registry, key, fn _ ->
|
||||
|
@ -31,7 +31,7 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do
|
|||
|
||||
@impl true
|
||||
def handle_cast({:add_client, client_pid, send_pid_back}, %{key: key} = state) do
|
||||
time = :erlang.monotonic_time()
|
||||
time = :erlang.monotonic_time(:millisecond)
|
||||
|
||||
{{conn_pid, _, _, _}, _} =
|
||||
Registry.update_value(@registry, key, fn {conn_pid, used_by, crf, last_reference} ->
|
||||
|
@ -116,6 +116,6 @@ defmodule Pleroma.Gun.ConnectionPool.Worker do
|
|||
|
||||
# LRFU policy: https://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.55.1478
|
||||
defp crf(time_delta, prev_crf) do
|
||||
1 + :math.pow(0.5, time_delta / 100) * prev_crf
|
||||
1 + :math.pow(0.5, 0.0001 * time_delta) * prev_crf
|
||||
end
|
||||